Contact: +256 392 102878 - Email: info@elite-consults.com

 

Elite Consulting Engineers contracted by APA Insurance (U) Ltd conducted a technical investigation for the failure of the Sodium Silicate Heavy Furnace Oil (HFO) fueled furnace belonging to their industrial client.

Services provided included:

  • Detailed materials inspection of furnace superstructure (crown and insulation), regenerator, associated chimney assemblies and documents of origination
  • Burner block and associated auxiliary equipment condition
  • Sampling and material testing of sillimanite bricks
  • Documentation of technical report

Contact Info

Elite Consulting Engineers Ltd

Mansfield Road, Makerere University

Engineers Ltd

CEDAT Building

Phone: +256-312102878/774126176

Email: info@elite-consults.com